Extron electronics SW USB Series Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Netzwerk-Switches Extron electronics SW USB Series herunter. Extron electronics SW USB Series User guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - SW USB Series

User GuideSW USB SeriesSwitchersUSB Switchers68-1517-01 Rev. F 02 12

Seite 2 - 安全须知 • 中文

SW USB Series • Installation 4InstallationThis section gives an overview of the steps to installing the SW USB Series switchers. It also provides a de

Seite 3 - FCC Class A Notice

SW USB Series • Installation 5Rear Panel FeaturesUSB SWITCHED INPUTUSB OUTPUT HUBTxTx RxRS-232CONTACT12RS-232PASS THRUUSB 3USB 1USB 2USB 40.7A MAX12V

Seite 4 - Trademarks

SW USB Series • Installation 6e Emulation DIP switches — (SW4 USB Plus only) These DIP switches enable host emulation to a keyboard and mouse connec

Seite 5 - Contents

SW USB Series • Installation 75. Use the supplied tie-wrap to strap the power cord to the extended tail of the connector.The figure below shows how

Seite 6 - SW USB Series • Contents vi

SW USB Series • Installation 8Wiring for RS-232 CommunicationRS-232 PortThe 3-pole, 3.5 mm captive screw connector labeled “RS-232” is used for optio

Seite 7 - Introduction

SW USB Series • Installation 9RS-232 Pass Thru PortThe RS-232 Pass Thru port loops the signal received at the SW USB RS-232 control port, the Contact

Seite 8 - Application Diagrams

SW USB Series • Installation 10Figure 7 App DiagramUSB SWITCHING INPUTTxTx RxRS-232CONTACT1234RS-232PASS THRUUSB OUTPUT HUBUSB 3USB 1PC 1PC 2PC 3PC 4

Seite 9 - SW4 VGA Ars

SW USB Series • Installation 11Connecting Multiple SW USBs in a SystemThe USB specification states that a maximum of five hubs (or five SW USBs) can

Seite 10 - Installation

SW USB Series • Operation 12OperationThis section provides a description of the SW USB front panel features and describes the procedures for performin

Seite 11 - Rear Panel Features

SW USB Series • Operation 13Active USB (port status) LEDs:d Input LEDs — Each of these green LEDs lights when a host or PC is connected to the corre

Seite 12 - Wiring the Power Connector

iiThis symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipm

Seite 13 - Connector

SW USB Series • Operation 14Selecting an input on an AV Switcher via contact closureTo make input selections on a connected AV switcher via contact c

Seite 14 - RS-232 Port

SW USB Series • Operation 15Mode SIS Command Commands Passed Through to an AV SwitcherLoop 1E 1LOOP }Only SIS commands received via the RS-232 contro

Seite 15 - RS-232 Pass Thru Port

SW USB Series • Operation 16Example: When a control system issues an SIS input selection command 1! (select input 1), 2! (select input 2), 3! (select

Seite 16 - Figure 7 App Diagram

SW USB Series • Operation 17ResettingTo reset the switcher to its factory default settings from the front panel:1. Disconnect power from the SW USB.

Seite 17 - SW4 USB Plus

SW USB Series • Operation 18NOTES: • If two mice or two keyboards are connected to output ports 3 and 4, and the appropriate emulation DIP switch is

Seite 18 - Operation

SW USB Series • Operation 19New firmware versions for the SW USB can be downloaded from the Extron web page. After you install the new firmware on yo

Seite 19 - Operations

SW USB Series • Operation 204. On the Add Device window, select your SW USB model from the Device Names drop-down menu.Figure 11. Device Name Drop-

Seite 20 - Selecting the loop mode

SW USB Series • Operation 21NOTES: • The original factory-installed firmware is permanently available on the SW USB. If the attempted firmware uploa

Seite 21 - SIS command processing

SW USB Series • Operation 2212. Click Begin. The following indicators on the Firmware Loader window show the progress of the update:• The Transfer T

Seite 22

SW USB Series • SIS Programming and Control 23SIS Programming and ControlThis section describes the connection through which the SW USB switchers can

Seite 23 - Resetting

iiiFCC Class A NoticeThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC R

Seite 24 - Updating Firmware

SW USB Series • SIS Programming and Control 24Error ResponsesIf the switcher is unable to execute a command it receives because the command is invali

Seite 25

SW USB Series • SIS Programming and Control 25Command and Response Table for SIS CommandsCommandASCII Command(Host to Unit)Response(Unit to Host)Addi

Seite 26

SW USB Series • SIS Programming and Control 26CommandASCII Command(Host to Unit)Response(Unit to Host)Additional DescriptionUpload FirmwareUpload rm

Seite 27 - SW USB Series • Operation 21

SW USB Series • Reference Information 27 2727Reference InformationThis section provides reference information on the SW USB Series. The following top

Seite 28

SW USB Series • Reference Information 28 28 28Temperature/humidity ... Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, nonco

Seite 29 - SIS Programming

SW USB Series • Reference Information 29 29 29Part Numbers and AccessoriesIncluded PartsIncluded PartReplacement Part NumberSW2 USB 60-952-02SW4 USB

Seite 30 - Symbol Definitions

SW USB Series • Reference Information 30 30 30Mounting the SW USB Series SwitcherThe SW USB Series switcher can be set on a table, mounted on a rack

Seite 31 - Example:

SW USB Series • Reference Information 31 31 31DiagramsHalfRackVersaToolsShelf(2) 4-40 x 3/16"ScrewsUse 2 mounting holes onopposite corners.Versa

Seite 32

SW USB Series • Reference Information 32 32 326. Insert #8 wood screws into the four pilot holes. Tighten each screw into the mounting surface until

Seite 33 - Information

Extron Headquarters+1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.863.1794 +1.714.491.1517 FAX +

Seite 34

ivConventions Used in this GuideIn this user guide, the following are used:CAUTION: A caution indicates a potential hazard to equipment or data.NOTE:

Seite 35 - Part Numbers and Accessories

SW USB Series • Contents vContentsIntroduction... 1About this Guide ...

Seite 36 - Rack Mounting

SW USB Series • Contents vi

Seite 37 - Furniture Mounting

SW USB Series • Introduction 1IntroductionThis section gives an overview of the Extron SW USB Series switchers. Topics include:• About this Guide• A

Seite 38

SW USB Series • Introduction 2• RS-232 control and pass-through — The SW USB switcher can be controlled by Simple Instruction Set (SIS™) commands re

Seite 39 - Extron Warranty

SW USB Series • Introduction 3100-240V 0.2A50-60HzREMOTEINPUTS1234OUTPUTOUTPUTLRSW6 VGA ArsUSB SWITCHING INPUTTxTx RxRS-232CONTACT1234RS-232PASS

Kommentare zu diesen Handbüchern

Keine Kommentare