User GuideSW USB SeriesSwitchersUSB Switchers68-1517-01 Rev. F 02 12
SW USB Series • Installation 4InstallationThis section gives an overview of the steps to installing the SW USB Series switchers. It also provides a de
SW USB Series • Installation 5Rear Panel FeaturesUSB SWITCHED INPUTUSB OUTPUT HUBTxTx RxRS-232CONTACT12RS-232PASS THRUUSB 3USB 1USB 2USB 40.7A MAX12V
SW USB Series • Installation 6e Emulation DIP switches — (SW4 USB Plus only) These DIP switches enable host emulation to a keyboard and mouse connec
SW USB Series • Installation 75. Use the supplied tie-wrap to strap the power cord to the extended tail of the connector.The figure below shows how
SW USB Series • Installation 8Wiring for RS-232 CommunicationRS-232 PortThe 3-pole, 3.5 mm captive screw connector labeled “RS-232” is used for optio
SW USB Series • Installation 9RS-232 Pass Thru PortThe RS-232 Pass Thru port loops the signal received at the SW USB RS-232 control port, the Contact
SW USB Series • Installation 10Figure 7 App DiagramUSB SWITCHING INPUTTxTx RxRS-232CONTACT1234RS-232PASS THRUUSB OUTPUT HUBUSB 3USB 1PC 1PC 2PC 3PC 4
SW USB Series • Installation 11Connecting Multiple SW USBs in a SystemThe USB specification states that a maximum of five hubs (or five SW USBs) can
SW USB Series • Operation 12OperationThis section provides a description of the SW USB front panel features and describes the procedures for performin
SW USB Series • Operation 13Active USB (port status) LEDs:d Input LEDs — Each of these green LEDs lights when a host or PC is connected to the corre
iiThis symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipm
SW USB Series • Operation 14Selecting an input on an AV Switcher via contact closureTo make input selections on a connected AV switcher via contact c
SW USB Series • Operation 15Mode SIS Command Commands Passed Through to an AV SwitcherLoop 1E 1LOOP }Only SIS commands received via the RS-232 contro
SW USB Series • Operation 16Example: When a control system issues an SIS input selection command 1! (select input 1), 2! (select input 2), 3! (select
SW USB Series • Operation 17ResettingTo reset the switcher to its factory default settings from the front panel:1. Disconnect power from the SW USB.
SW USB Series • Operation 18NOTES: • If two mice or two keyboards are connected to output ports 3 and 4, and the appropriate emulation DIP switch is
SW USB Series • Operation 19New firmware versions for the SW USB can be downloaded from the Extron web page. After you install the new firmware on yo
SW USB Series • Operation 204. On the Add Device window, select your SW USB model from the Device Names drop-down menu.Figure 11. Device Name Drop-
SW USB Series • Operation 21NOTES: • The original factory-installed firmware is permanently available on the SW USB. If the attempted firmware uploa
SW USB Series • Operation 2212. Click Begin. The following indicators on the Firmware Loader window show the progress of the update:• The Transfer T
SW USB Series • SIS Programming and Control 23SIS Programming and ControlThis section describes the connection through which the SW USB switchers can
iiiFCC Class A NoticeThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC R
SW USB Series • SIS Programming and Control 24Error ResponsesIf the switcher is unable to execute a command it receives because the command is invali
SW USB Series • SIS Programming and Control 25Command and Response Table for SIS CommandsCommandASCII Command(Host to Unit)Response(Unit to Host)Addi
SW USB Series • SIS Programming and Control 26CommandASCII Command(Host to Unit)Response(Unit to Host)Additional DescriptionUpload FirmwareUpload rm
SW USB Series • Reference Information 27 2727Reference InformationThis section provides reference information on the SW USB Series. The following top
SW USB Series • Reference Information 28 28 28Temperature/humidity ... Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, nonco
SW USB Series • Reference Information 29 29 29Part Numbers and AccessoriesIncluded PartsIncluded PartReplacement Part NumberSW2 USB 60-952-02SW4 USB
SW USB Series • Reference Information 30 30 30Mounting the SW USB Series SwitcherThe SW USB Series switcher can be set on a table, mounted on a rack
SW USB Series • Reference Information 31 31 31DiagramsHalfRackVersaToolsShelf(2) 4-40 x 3/16"ScrewsUse 2 mounting holes onopposite corners.Versa
SW USB Series • Reference Information 32 32 326. Insert #8 wood screws into the four pilot holes. Tighten each screw into the mounting surface until
Extron Headquarters+1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.863.1794 +1.714.491.1517 FAX +
ivConventions Used in this GuideIn this user guide, the following are used:CAUTION: A caution indicates a potential hazard to equipment or data.NOTE:
SW USB Series • Contents vContentsIntroduction... 1About this Guide ...
SW USB Series • Contents vi
SW USB Series • Introduction 1IntroductionThis section gives an overview of the Extron SW USB Series switchers. Topics include:• About this Guide• A
SW USB Series • Introduction 2• RS-232 control and pass-through — The SW USB switcher can be controlled by Simple Instruction Set (SIS™) commands re
SW USB Series • Introduction 3100-240V 0.2A50-60HzREMOTEINPUTS1234OUTPUTOUTPUTLRSW6 VGA ArsUSB SWITCHING INPUTTxTx RxRS-232CONTACT1234RS-232PASS