Extender Plus Series • Setup Guide
ATTENTION: Potential Damage to Property. Installation and service must be
performed by authorized personnel only. These products must be used with UL approved,
grounded electrical boxes.
Step 1
Configure EDID Minder at the display device. The Extender Plus models offer two ways of
conguring EDID:
• EDID Record — Enables the device to record EDID
directly from a display.
1. Turn the rotary switch (a) to position 0.
NOTE: The DIP switch positions have no
effect in this mode.
2. Apply power to the Extender by connecting the
12 VDC power supply. The green LED (b) lights
when power is available.
3. Connect the display device to the input of the Extender using a VGA cable.
4. Power on the display device.
5. Press and release the recessed EDID store button (c). The LED ashes red while
storing the EDID, then it turns solid green when the EDID data has been stored. The
display can now be disconnected.
NOTE: If an external supply was used for recording, it can now be disconnected.
• Pre-programmed EDID — The Extender Plus models contain pre‑programmed EDIDs with
the most common display native resolutions for both 50 and 60 Hz.
1. See Table 1 on page 9 of the Extender Plus Series User Guide to see which
resolution corresponds to each rotary switch (a) position. Set the rotary switch to
the native resolution of the display.
2. Set the rst DIP switch (d) to the vertical refresh frequency of the display (default is
ON, 60Hz).
Step 2
Turn all of the equipment off and disconnect the power cords from the power source.
Step 3
Select the installation location and install the electrical wall box. See “Installation
Instructions” on page 2 of the Extender Plus Series User Guide for details on installing the
wall box and cables.
NOTE: The Extron Extender Plus AAP does not require a wall box if it is installed into an
Extron HSA 400 Series or HSA 800 Series surface access product.