Refer also to the MTPX Plus User’s Manual at www.extron.com.
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
IP setup
Set IP address
EX2^
CI
}
Ipi
X2^]
Read IP address
E
CI
} X2^]
Set subnet mask
EX2^
CS
}
Ips
X2^]
Read subnet mask
E
CS
} X2^]
Set gateway IP address
EX2^
CG
}
Ipg
X2^]
Read gateway IP address
E
CG
} X2^]
Set DHCP on or off
EX2&
DH
}
Idh
X2&]
Read DHCP on/off status
E
DH
} X2&]
Set verbose mode
EX2*
CV
}
Vrb
X2*]
Read verbose mode
E
CV
} X2*]
Configure current port timeout
E
0*
X2(
TC
}
Pti0*
X2(]
Read current port timeout
E
0TC
} X2(]
Configure global IP port timeout
E
1*
X2(
TC
}
Pti1*
X2(]
Read global IP port timeout
E
1TC
} X2(]
N
X2^
= IP address ###.###.###.###
X2&
= DHCP 0 =1 off, 1 = on
X2*
= Verbose mode 0 = clear/none (default for Telnet connection)
1 = verbose mode (default for RS-232/RS-422 connection)
2 = tagged responses for queries
3 = verbose mode and tagged for queries
X2(
= Port timeout interval 1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)
MTPX Plus • Remote Control and Optimizing the Video