WindoWall Pro Series • Reference Information 81
7. On the Open dialog box, navigate to the new firmware file, which has an S19 extension,
and double-click it.
Figure 58. Open Dialog Box for Firmware File Selection
ATTENTION: Valid firmware files must have the file extension S19. A file with any
other extension is not a firmware upgrade for this product and could cause the
WindoWall Pro to stop functioning.
NOTES:
The original factory-installed firmware is permanently available on the
WindoWall Pro. If the attempted firmware upload fails for any reason, the
WindoWall Pro reverts to the factory version.
When downloaded from the Extron website, by default the firmware is placed in
a folder at:
C:\Program Files\Extron\Firmware\MGP Pro (Windows XP) or
C:\Program Files (x86)\Extron\Firmware\MGP Pro (Windows 7).
On the Add Device dialog box, the path to the new firmware file is displayed in the Path
field.